{"title":"Convertidores de Fase Estaticos para operar Motores trifasicos a 60% de potencia","description":"\u003cp class=\"MsoNormal\" style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003ci style=\"mso-bidi-font-style: normal;\"\u003e\u003cspan style=\"font-size: 48.0pt; line-height: 115%; font-family: 'Georgia','serif'; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi;\"\u003eAUcontrols\u003c\/span\u003e\u003c\/i\u003e\u003c\/strong\u003e\u003ci style=\"mso-bidi-font-style: normal;\"\u003e\u003cspan style=\"font-size: 48.0pt; line-height: 115%; font-family: 'Georgia','serif';\"\u003e\u003c\/span\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan lang=\"ES-MX\" style=\"font-family: 'Verdana','sans-serif'; mso-ansi-language: ES-MX;\"\u003eConvertidores de Fase Estáticos con los cuales obtendrá 2\/3 de la potencia del motor que opera. Haga funcionar su Motor Trifásico de 230 VCA con alimentación Monofásica de 230 VCA. Estos Convertidores Estáticos son únicamente para Motores Trifásicos. Para Potencias desde: 1 HP hasta 15 HP. Para cargas ligeras a medianamente cargadas.  Tenga en Mente que solo le dará 2\/3 de la potencia del Motor. \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan lang=\"ES-MX\" style=\"font-family: 'Verdana','sans-serif'; mso-ansi-language: ES-MX;\"\u003eUso Industrial, 1 año de garantía.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan lang=\"ES-MX\" style=\"font-family: 'Verdana','sans-serif'; mso-ansi-language: ES-MX;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\u003cstrong\u003e\u003cspan lang=\"ES-MX\" style=\"font-family: 'Verdana','sans-serif'; mso-ansi-language: ES-MX;\"\u003eNOTA IMPORTANTE:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\u003cspan lang=\"ES-MX\" style=\"font-family: 'Verdana','sans-serif'; mso-ansi-language: ES-MX;\"\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eNo compre un Convertidor de Fase Estático más grande que los HP de su Motor pensando que obtendrá más potencia. Los Convertidores de Fase Estáticos solo son buenos para los HP para lo que fueron diseñados. El Convertidor de fase Estático debe coincidir con la potencia de su Motor o estar dentro del rango de los HP del Motor, de lo contrario tendrá problemas al arrancar el motor y NO funcionará.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e \u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\u003cspan lang=\"ES-MX\" style=\"font-family: 'Verdana','sans-serif'; mso-ansi-language: ES-MX;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eConsultenos en: info@aucontrols.com\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"static-phase-converters-run-3-phase-motors-with-230v-single-phase-mod-aspc-3hd","title":"Static Phase Converter runs 1~3HP, 230VAC, 3-Phase Motors w\/Single Phase Power","description":"\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal; mso-outline-level: 2;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003ci\u003e\u003cspan style=\"font-size: 28.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eAUcontrols.\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; margin-bottom: 12.0pt; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eStatic Phase Converter Mod: ASPC-3HD\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eRuns \u003c\/b\u003e\u003c\/span\u003e\u003cb style=\"font-family: Verdana, 'sans-serif'; font-size: 16px;\"\u003e1 to 3 HP, 3-Phase, \u003c\/b\u003e\u003cb style=\"font-family: Verdana, 'sans-serif'; font-size: 12pt;\"\u003e230VAC \u003c\/b\u003e\u003cb style=\"font-family: Verdana, 'sans-serif'; font-size: 12pt;\"\u003eMOTORS with Single Phase Power  \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 12pt; line-height: normal; text-align: center;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cb\u003eStatic Phase Converters will give ONLY 60% of the Motor's HP.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 12pt; line-height: normal; text-align: center;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eDESIGNED FOR LIGHT TO MEDIUM LOADS (MOTORS ONLY!)\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHP Range: Min: 1 - Max: 3.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInput Power Supply: Single Phase 208 - 240 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSingle Phase FLA: 9.6 Amps. Max.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: 6\" X 6\" X 4\".\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e1 Year Warranty.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eIMPORTAT\u003c\/span\u003e\u003c\/b\u003e:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; Do not buy a bigger Static Phase Converter than your Motor's HP thinking that you will get more power. It will NOT run, nor get a smaller Converter because it will not work either! Static Phase Converters DO NOT generate the 3rd Phase! \u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt;Your Motor HP has to be between the Static Phase Converters HP to run properly.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; If you are using a Motor Starter make sure the Motor Starter's Contactor's coil is fed from L1 \u0026amp; L2 (230VAC) otherwise it will not start.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; You Can Run: Lathes not fitted with clutch, Milling \u0026amp; Drilling machines, Saws, etc. \u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eWA\u003c\/span\u003e\u003c\/b\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eRNING!\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; For Air Compressors, blowers, water pumps and hydraulic pumps with pulley, the Motor's pulley diameter MUST BE REDUCED 1\/3 or a 50% larger Motor can be fitted.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eYou can use your motor with heavy starting cycles, frequent starting, instant reversing, etc.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"line-height: normal; text-align: center;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cu\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eKeep in mind that Static Phase Converters will ONLY GIVE 60% OF MOTOR's rated HP.\u003c\/span\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Static Phase Converters\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/Static_Phase_Converter_Instructions.pdf?v=1631199941\"\u003e\u003cstrong\u003eInstallation Diagram Click Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h2\u003e","brand":"AUcontrols","offers":[{"title":"Phase Converter","offer_id":55251980058783,"sku":"","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/products\/ASPC-3HD-1.jpg?v=1652654438"},{"product_id":"static-phase-converter-aspc-5hd","title":"RUN 3-Phase Motors 3 to 5HP, 230VAC, with Static Phase Converters","description":"\u003cp style=\"line-height: normal; text-align: center;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003ci\u003e\u003cspan style=\"font-size: 26.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 18.0pt;\"\u003eAUcontrols\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"font-size: 26.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 18.0pt;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eStatic Phase Converter for 3 to 5 HP – 230V, 3-Phase Motors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Verdana','sans-serif';\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\" data-start=\"313\" data-end=\"513\"\u003e\u003cstrong data-start=\"313\" data-end=\"369\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eRun 3-Phase Motors Using 208–240V Single-Phase Power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\" data-start=\"313\" data-end=\"513\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 8.0pt; font-family: 'Verdana','sans-serif';\"\u003e\u003c\/span\u003e\u003cspan style=\"font-family: 'MS Mincho'; mso-ascii-font-family: Verdana; mso-bidi-font-family: 'MS Mincho';\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003cstrong data-start=\"374\" data-end=\"417\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eOperates at 60% of the motor’s rated HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e\u003cbr data-start=\"417\" data-end=\"420\"\u003e\u003c\/span\u003e\u003cspan style=\"font-family: 'MS Mincho'; mso-ascii-font-family: Verdana; mso-bidi-font-family: 'MS Mincho';\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003cstrong data-start=\"422\" data-end=\"461\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eDesigned to run 3-phase motors only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e\u003cbr data-start=\"461\" data-end=\"464\"\u003e\u003c\/span\u003e\u003cspan style=\"font-family: 'MS Mincho'; mso-ascii-font-family: Verdana; mso-bidi-font-family: 'MS Mincho';\"\u003e✔\u003c\/span\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e Ideal for \u003c\/span\u003e\u003cstrong data-start=\"476\" data-end=\"500\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003elight to medium load\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e applications\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\" data-start=\"515\" data-end=\"518\"\u003e\u003c\/div\u003e\n\u003ch4 align=\"center\" style=\"margin-top: 0in; text-align: center; line-height: normal;\" data-start=\"520\" data-end=\"547\"\u003e\n\u003cspan style=\"font-size: 12.0pt; mso-ascii-font-family: Verdana; mso-hansi-font-family: Cambria; mso-bidi-font-family: Cambria;\"\u003e⚙️\u003c\/span\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003cstrong data-start=\"528\" data-end=\"547\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: major-bidi; color: windowtext; font-style: normal; mso-bidi-font-style: italic;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; text-align: justify; line-height: normal;\"\u003e\u003cspan style=\"font-size: 8.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l1 level1 lfo1; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eHP Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e 3 to 5 HP (motor must be within this range)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l1 level1 lfo1; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"612\" data-end=\"668\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"612\" data-end=\"630\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eInput Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e 208–240 VAC, 50\/60 Hz, Single Phase\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l1 level1 lfo1; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"671\" data-end=\"705\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"671\" data-end=\"695\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eInput Current (FLA):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e 15 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l1 level1 lfo1; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"708\" data-end=\"738\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"708\" data-end=\"723\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e 8\" x 8\" x 4\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l1 level1 lfo1; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"741\" data-end=\"761\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"741\" data-end=\"754\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eWarranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e 1 Year\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\" data-start=\"763\" data-end=\"766\"\u003e\u003c\/div\u003e\n\u003ch3 align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\" data-start=\"768\" data-end=\"800\"\u003e\n\u003cspan style=\"font-size: 12.0pt;\"\u003e⚠️\u003c\/span\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003cstrong data-start=\"775\" data-end=\"800\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eIMPORTANT USAGE NOTES\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif';\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003ch3 align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\u003cspan style=\"font-size: 8.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp style=\"text-indent: -.25in; mso-list: l2 level1 lfo2; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"804\" data-end=\"1118\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"804\" data-end=\"856\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eDo not use an oversized or undersized converter!\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e\u003cbr data-start=\"856\" data-end=\"859\"\u003eA larger converter \u003c\/span\u003e\u003cstrong data-start=\"880\" data-end=\"908\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003ewill not give more power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e and may prevent startup, also a smaller converter \u003c\/span\u003e\u003cstrong data-start=\"958\" data-end=\"975\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003ewill not work\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0in 0in .0001pt .5in;\" data-start=\"1122\" data-end=\"1326\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong data-start=\"981\" data-end=\"1044\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eStatic Phase Converters do not generate a true third phase.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e The motor must match the converter’s rated HP range for proper operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; margin: 0in 0in .0001pt .5in;\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level1 lfo2; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"1122\" data-end=\"1326\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eIf your machine has a motor starter\/contactor\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e, the contactor coil \u003c\/span\u003e\u003cstrong data-start=\"1205\" data-end=\"1245\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003emust be powered by L1 \u0026amp; L2 (230 VAC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; margin: 0in 0in .0001pt .5in;\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level1 lfo2; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"1330\" data-end=\"1358\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cstrong data-start=\"1330\" data-end=\"1356\"\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol; font-weight: normal;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c!--[endif]--\u003e\u003cstrong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eApproved Uses Include:\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; font-weight: normal;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0in; margin-bottom: .0001pt; text-align: justify;\" data-start=\"1363\" data-end=\"1389\"\u003e\u003cspan style=\"font-size: 8.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level2 lfo2; tab-stops: list 1.0in; margin: 0in 0in .0001pt 1.0in;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Courier New'; mso-fareast-font-family: 'Courier New';\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003eo\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eLathes (non-clutch type)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level2 lfo2; tab-stops: list 1.0in; margin: 0in 0in .0001pt 1.0in;\" data-start=\"1394\" data-end=\"1412\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Courier New'; mso-fareast-font-family: 'Courier New';\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003eo\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eMilling machines\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level2 lfo2; tab-stops: list 1.0in; margin: 0in 0in .0001pt 1.0in;\" data-start=\"1417\" data-end=\"1436\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Courier New'; mso-fareast-font-family: 'Courier New';\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003eo\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eDrilling machines\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level2 lfo2; tab-stops: list 1.0in; margin: 0in 0in .0001pt 1.0in;\" data-start=\"1441\" data-end=\"1447\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Courier New'; mso-fareast-font-family: 'Courier New';\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003eo\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eSaws\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; text-indent: -.25in; mso-list: l2 level2 lfo2; tab-stops: list 1.0in; margin: 0in 0in .0001pt 1.0in;\" data-start=\"1452\" data-end=\"1503\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: 'Courier New'; mso-fareast-font-family: 'Courier New';\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003eo\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eOther machinery designed for light to moderate duty\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003chr size=\"2\" width=\"100%\" align=\"center\" data-start=\"1505\" data-end=\"1508\"\u003e\u003c\/div\u003e\n\u003ch3 align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\" data-start=\"1510\" data-end=\"1571\"\u003e\n\u003cspan style=\"font-size: 12.0pt;\"\u003e⚠️\u003c\/span\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif';\"\u003e SPECIAL INSTRUCTIONS for COMPRESSORS, PUMPS, AND FANS:\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ch3 align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\u003cspan style=\"font-size: 8.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp style=\"margin: 0in; margin-bottom: .0001pt;\" data-start=\"1573\" data-end=\"1655\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eFor motors powering \u003c\/span\u003e\u003cstrong data-start=\"1593\" data-end=\"1654\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eair compressors, blowers, water pumps, or hydraulic pumps\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0in; margin-bottom: .0001pt;\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -.25in; mso-list: l0 level1 lfo3; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"1659\" data-end=\"1719\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"1659\" data-end=\"1704\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eReduce the motor’s pulley diameter by 1\/3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e\u003cbr data-start=\"1704\" data-end=\"1707\"\u003e\u003cem data-start=\"1711\" data-end=\"1715\"\u003e\u003cb\u003eOR\u003c\/b\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-indent: -.25in; mso-list: l0 level1 lfo3; tab-stops: list .5in; margin: 0in 0in .0001pt .5in;\" data-start=\"1722\" data-end=\"1770\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"font-size: 10.0pt; mso-bidi-font-size: 12.0pt; font-family: Symbol; mso-fareast-font-family: Symbol; mso-bidi-font-family: Symbol;\"\u003e\u003cspan style=\"mso-list: Ignore;\"\u003e·\u003cspan style=\"font: 7.0pt 'Times New Roman';\"\u003e         \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cstrong data-start=\"1722\" data-end=\"1756\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eUse a motor that is 50% larger\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify; margin: 0in 0in .0001pt .5in;\" data-start=\"1772\" data-end=\"1844\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003eThis ensures the motor starts under load and avoids overload or failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0in; margin-bottom: .0001pt; text-align: justify;\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"margin: 0in; margin-bottom: .0001pt; text-align: center;\" data-start=\"1848\" data-end=\"1961\"\u003e\u003cstrong data-start=\"1848\" data-end=\"1861\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eReminder:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e Static Phase Converters will only provide \u003c\/span\u003e\u003cstrong data-start=\"1904\" data-end=\"1925\"\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-fareast-theme-font: major-fareast;\"\u003eapproximately 60%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-family: 'Verdana','sans-serif';\"\u003e of the motor’s rated horsepower.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Static Phase Converters\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/Static_Phase_Converter_Instructions.pdf?v=1631199941\"\u003e\u003cstrong\u003eInstallation Diagram Click Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"AUcontrols","offers":[{"title":"Static Converter","offer_id":55251979403423,"sku":"","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/products\/ASPC-5HD-7.jpg?v=1624749176"},{"product_id":"static-phase-converter-aspc-7hd","title":"Static Phase Converter for 4 to 8HP, 230VAC, 3-Phase Motors. Mod. ASPC-7HD","description":"\u003cp class=\"MsoNormal\" align=\"center\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal; mso-outline-level: 2;\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003ci\u003e\u003cspan style=\"font-size: 28.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eAUcontrols.\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; margin-bottom: 12.0pt; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eStatic Phase Converter Mod: ASPC-7HD (Heavy Duty)\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eRuns 3 Phase MOTORS with Single Phase Power 230VAC \u003c\/b\u003e\u003cbr\u003e\u003cb\u003e4 to 8 HP, 3-Phase Motors using Single Phase Power\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eStatic Phase Converters will give ONLY 60% of the Motor's HP.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDESIGNED FOR LIGHT TO MEDIUM LOADS (MOTORS ONLY!)\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHP Range: Min: 4 - Max: 8.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInput Power Supply: Single Phase 208 - 240 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSingle Phase FLA: 22 Amps.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: 8\" X 8\" X 4\".\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e1 Year Warranty.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eIMPORTANT:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; Do not buy a bigger Static Phase Converter than your Motor's HP thinking that you will get more power. It will NOT run, nor get a smaller Converter because it will not work either! Static Phase Converters DO NOT generate the 3rd Phase! \u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt;Your Motor HP has to be between the Static Phase Converters HP to run properly.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; If you are using a Motor Starter make sure the Motor Starter's Contactor's coil is fed from L1 \u0026amp; L2 (230VAC) otherwise it will not start.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; You Can Run: Lathes not fitted with clutch, Milling \u0026amp; Drilling machines, Saws, etc. \u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eWARNING\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; For Air Compressors, blowers, water pumps and hydraulic pumps with pulley, the Motor's pulley diameter MUST BE REDUCED 1\/3 or a 50% larger Motor can be fitted.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eYou can use your motor with heavy starting cycles, frequent starting, instant reversing, etc.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cb\u003e\u003cu\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eKeep in mind that Static Phase Converters will ONLY GIVE 60% OF MOTOR's rated HP.\u003c\/span\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Static Phase Converters\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/Static_Phase_Converter_Instructions.pdf?v=1631199941\"\u003e\u003cstrong\u003eInstallation Diagram Click Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h2\u003e","brand":"AUcontrols","offers":[{"title":"Phase Converter","offer_id":55251979862175,"sku":"","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/products\/ASPC-7HD-1.jpg?v=1622559566"},{"product_id":"static-phase-converters-run-3-phase-motors-w-single-230v-mod-aspc-10hd","title":"Static Phase Converter for 8~12HP, 230VAC, 3-Phase Motors, Mod. ASPC-10HD","description":"\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal; mso-outline-level: 2;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003ci\u003e\u003cspan style=\"font-size: 28.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eAUcontrols.\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" align=\"center\" style=\"mso-margin-top-alt: auto; margin-bottom: 12.0pt; text-align: center; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eStatic Phase Converter Mod: ASPC-10HD (Heavy Duty)\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eRuns 3 Phase, 230V MOTORS with Single Phase Power 230VAC \u003c\/b\u003e\u003cbr\u003e\u003cb\u003eStatic Phase Converters will give ONLY 60% of the Motor's rated HP.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDESIGNED FOR LIGHT TO MEDIUM LOADS (MOTORS ONLY!)\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHP Range: Min: 8 - Max: 12.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInput Power Supply: Single Phase 208 - 240 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSingle Phase FLA: 33 Amps.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: 8\" X 8\" X 4\".\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e1 Year Warranty.\u003c\/b\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eIMPORTANT:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; Do not buy a bigger Static Phase Converter than your Motor's HP thinking that you will get more power. It will NOT run, nor get a smaller Converter because it will not work either! Static Phase Converters DO NOT generate the 3rd Phase! \u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt;Your Motor HP has to be between the Static Phase Converters HP to run properly.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; If you are using a Motor Starter make sure the Motor Starter's Contactor's coil is fed from L1 \u0026amp; L2 (230VAC) otherwise it will not start.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; You Can Run: Lathes not fitted with clutch, Milling \u0026amp; Drilling machines, Saws, etc. \u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eWARNING\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; For Air Compressors, blowers, water pumps and hydraulic pumps with pulley, the Motor's pulley diameter MUST BE REDUCED 1\/3 or a 50% larger Motor can be fitted.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eYou can use your motor with heavy starting cycles, frequent starting, instant reversing, etc.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"line-height: normal; text-align: center;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cu\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eKeep in mind that Static Phase Converters will ONLY GIVE 60% OF MOTOR's rated HP.\u003c\/span\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca style=\"color: #ff2a00;\" title=\"Static Phase Converters\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/Static_Phase_Converter_Instructions.pdf?v=1631199941\"\u003e\u003cstrong\u003eInstallation Diagram Click Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h2\u003e","brand":"AUcontrols","offers":[{"title":"Phase Converter","offer_id":55251979763871,"sku":"","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/products\/ASPC-10HD-3.jpg?v=1615339094"},{"product_id":"static-phase-conveter-aspc-15hd","title":"Static Phase Conveter ASPC-15HD For 12 ~ 18HP, 230VAC, 3-Phase Motors.","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal; mso-outline-level: 2;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003ci\u003e\u003cspan style=\"font-size: 28.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eAUcontrols.\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Times New Roman','serif'; mso-fareast-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; margin-bottom: 12.0pt; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eStatic Phase Converter Mod: ASPC-15HD (Heavy Duty)\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eRuns 3 Phase MOTORS with Single Phase Power 230VAC \u003c\/b\u003e\u003cbr\u003e\u003cb\u003e12 to 18 HP, 3-Phase Motors using Single Phase Power\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eStatic Phase Converters will give ONLY 60% of the Motor's HP.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDESIGNED FOR LIGHT TO MEDIUM LOADS (MOTORS ONLY!)\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHP Range: Min: 12 - Max: 18.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInput Power Supply: Single Phase 208 - 240 VAC\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSingle Phase FLA: 45 Amps.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: 8\" X 8\" X 4\".\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e1 Year Warranty.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eIMPORTANT:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; Do not buy a bigger Static Phase Converter than your Motor's HP thinking that you will get more power. It will NOT run, nor get a smaller Converter because it will not work either! Static Phase Converters DO NOT generate the 3rd Phase! \u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt;Your Motor HP has to be between the Static Phase Converters HP to run properly.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; If you are using a Motor Starter make sure the Motor Starter's Contactor's coil is fed from L1 \u0026amp; L2 (230VAC) otherwise it will not start.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; You Can Run: Lathes not fitted with clutch, Milling \u0026amp; Drilling machines, Saws, etc. \u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; text-align: center; line-height: normal;\" align=\"center\" class=\"MsoNormal\"\u003e\u003cb style=\"mso-bidi-font-weight: normal;\"\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eWARNING\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u0026gt; For Air Compressors, blowers, water pumps and hydraulic pumps with pulley, the Motor's pulley diameter MUST BE REDUCED 1\/3 or a 50% larger Motor can be fitted.\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eYou can use your motor with heavy starting cycles, frequent starting, instant reversing, etc.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cb\u003e\u003cu\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eKeep in mind that Static Phase Converters will ONLY GIVE 60% OF MOTOR's rated HP.\u003c\/span\u003e\u003c\/u\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: .0001pt; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif';\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/Static_Phase_Converter_Instructions.pdf?v=1631199941\" title=\"Static Phase Converters\" style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInstallation Diagram Click Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003ePicture only for reference\u003c\/span\u003e.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AUcontrols","offers":[{"title":"Static Phase Converter \/ Single to 3-Phase Power","offer_id":55251977830559,"sku":"","price":680.0,"currency_code":"USD","in_stock":true},{"title":"Static Phase Converter \/ PHASE CONVERTER","offer_id":55251978715295,"sku":"","price":680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/products\/20200611_181832_ba4b2a47-cb9e-4a17-b5c9-f92e51e08d83.jpg?v=1610142147"},{"product_id":"static-phase-converter-with-booster-aspc-5hdb-for-3-5-hp-230vac-3-phase-motors","title":"Static Converter WITH BOOSTER, Mod. ASPC-5HDB For: 3~5 HP, 230VAC, 3-Phase Motors","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cb\u003e\u003ci\u003e\u003cspan style=\"font-size: 26.0pt; font-family: 'Georgia','serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 18.0pt;\"\u003eAUcontrols\u003c\/span\u003e\u003c\/i\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal; mso-outline-level: 3;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eStatic Phase Converter with BOOSTER for 3 to 5HP,230V, 3-Phase Motors. Mod. ASPC-5HD\u003c\/span\u003e\u003c\/b\u003e\u003cb style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eB\u003c\/span\u003e\u003c\/b\u003e\u003cb style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e, Made in USA.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003eRUN 3-Phase, Motors with 208-240 VAC Single Phase Power\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cbr\u003e\u003cb\u003eAT 75~80\u003c\/b\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 12.0pt; font-family: 'Verdana','sans-serif'; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman';\"\u003e\u003cb\u003e% OF MOTOR'S RATED HP.\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDESIGNED TO RUN 3-Phase, \u003cspan style=\"text-transform: uppercase;\"\u003eMotors ONLY\u003c\/span\u003e!\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eFOR MEDIUM to ALMOST FULL LOADS\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eHP Range: Min: 3   Max: 5.\u003c\/b\u003e \u003cbr\u003e\u003cb\u003ePower Supply: Single Phase 208 - 240 VAC 50\/60 Hz.\u003c\/b\u003e \u003cbr\u003e\u003cb\u003eSingle Phase FLA: 15 Amps\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eDimensions: 8\" X 8\" X 4\".\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e1 Year Warranty.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003e                                                    \u003cstrong\u003e\u003cu\u003e\u003cspan style=\"font-size: 16.0pt; font-family: 'Verdana','sans-serif'; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi;\"\u003eIMPORTANT:\u003c\/span\u003e\u003c\/u\u003e\u003c\/strong\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003e\u0026gt; Do not buy a bigger Static Phase Converter than your Motor's HP thinking that you will get more power . It will NOT run, nor get a smaller Converter because it will not work either! Static Phase Converters DO NOT generate the 3rd Phase! \u003c\/b\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003e\u0026gt;Your Motor HP has to be between the Static Phase Converter HP to run properly.\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003cb\u003e\u0026gt; If you are using a Motor Starter make sure the Motor Starter's Contactor's coil is fed from L1 \u0026amp; L2 (230VAC) otherwise it will not start.\u003c\/b\u003e\u003cbr\u003e\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003e\u0026gt; You Can Run: Lathes not fitted with clutch, Milling \u0026amp; Drilling machines, Saws, etc.\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003e\u0026gt; For Air Compressors, blowers, water pumps and hyraulic pumps with pulley, the Motor's pulley diameter MUST BE REDUCED 1\/3 or a 50% larger Motor can be fitted.\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003eYou can use your motor with heavy starting cyles, frequent starting, instant reversing, etc.\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan\u003e\u003cspan size=\"5\" face=\"Arial Black\"\u003e\u003cb\u003eKeep in mind this Static Phase Converters with Booster will GIVE 75 ~ 80% of MOTOR's rated HP.\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/Static_Phase_Converter_Instructions.pdf?v=1631199941\" title=\"Static Phase Converters\"\u003e\u003cstrong\u003eInstallation Diagram Click Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/h2\u003e","brand":"AUcontrols","offers":[{"title":"Default Title","offer_id":42717178200223,"sku":"","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/files\/ASPC-5HD-6_b22a34e9-89a3-412f-aa7a-4e8e81592b75.jpg?v=1711462182"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0486\/9947\/4079\/collections\/ASPC-10HD-2.jpg?v=1616287130","url":"https:\/\/aucontrols.com\/collections\/convertidores-de-fase-estaticos-uso-industrial.oembed","provider":"AUcontrols","version":"1.0","type":"link"}